Engineering RFQs answered within 1 business dayrfq@technicalfoamservices.com

Engineering tool

Technical foam material selector & gasket force calculator

Set the application, temperature envelope, standards and exposure. Get the grades that meet every requirement, the closest trade-offs, and the closure force at your deflection.

Units
Application
Operating temperature

Min must be at or below max.

Required standards
Environmental exposure
Gasket compression force (optional)

25%–30% is the sealing sweet spot for closed-cell sponge and PORON® / BISCO®; higher deflection risks permanent compression set.

Matching…

How materials are matched

Twelve curated grades (PORON® 4701-30 / -40 / -50, BISCO® HT-800, Plastazote® LD45, Basotect®, EPDM 2A1 / 2A2 / 2A3, neoprene 2C2, conductive XLPE, PU ester / ether) are checked against:

  • the application (each grade lists where it is a normal choice);
  • the continuous temperature envelope from the data sheet;
  • every standard you tick (listing or test data on that grade);
  • exposure: UV resistance, oil resistance, closed-cell structure for immersion, low outgassing.

Grades that meet everything are exact matches. Grades that miss one or two requirements are shown as trade-offs, with the reason and an upgrade path.

Closure force

F = CFD@25% × k × contact area

DeflectionFactor k
15%0.65 × CFD25
25%1.00 × CFD25
30%1.25 × CFD25
40%1.85 × CFD25
50%2.65 × CFD25

Foam stiffens non-linearly as cells collapse, so force at 50% is about 2.65 times the 25% value. Use the upper end of the range to size fasteners and flange stiffness.

Formula and data sources are published on About → Methodology. Estimates are engineering guidance, confirmed at drawing review against the manufacturer TDS.