Decoding the callout
Type: 1 or 2
1 = open-cell sponge. 2 = closed-cell expanded rubber. Gaskets that must seal against water are almost always Type 2.
Class: A to D
A non-oil-resistant (EPDM). B oil resistant, low swell (nitrile). C oil resistant, medium swell (neoprene). D extreme temperature (silicone).
Grade: 0 to 5
Compression force deflection at 25%, from Grade 0 (softest) to Grade 5 (firmest). See the table below.
CFD grade table
| Grade | CFD @ 25% (psi) | CFD @ 25% (kPa) | Typical use |
|---|---|---|---|
| 0 | 0–2 | 0–13.8 | Very low closure force, thin covers |
| 1 | 2–5 | 13.8–34.5 | Light-duty enclosures, sheet-metal doors |
| 2 | 5–9 | 34.5–62.1 | General enclosure and HVAC seals (most common) |
| 3 | 9–13 | 62.1–89.6 | Higher bolt load, vibration |
| 4 | 13–17 | 89.6–117.2 | Firm seals, heavy covers |
| 5 | 17–25 | 117.2–172.4 | Very firm, structural spacers |
Common callouts
| Callout | Polymer | CFD @ 25% | Temperature | Where it is used |
|---|---|---|---|---|
| 2A1 | EPDM | 2–5 psi | −40 to +105°C | Low-force outdoor seals, light enclosures |
| 2A2 | EPDM | 5–9 psi | −40 to +105°C | HVAC, electrical enclosures, outdoor cabinets |
| 2A3 | EPDM | 9–13 psi | −40 to +105°C | High bolt-load environmental gaskets |
| 2B2 | Nitrile (NBR) blend | 5–9 psi | Polymer dependent | Fuel and oil contact, low swell |
| 2C2 | Neoprene / CR blend | 5–9 psi | −40 to +93°C | Moderate oil, general industrial, HF-1 grades |
| 2D2 | Silicone | 5–9 psi | Wide (silicone) | High and low temperature extremes |
EPDM or neoprene?
- EPDM (Class A): the best weather, UV and ozone resistance of the common sponges and the lowest cost ($0.85–$2.80/ft² at 1/8"–1/4"). Swells in oil and fuel.
- Neoprene / CR blends (Class C): medium oil and fuel resistance with good weathering, and UL 94 HF-1 on listed grades. Costs a little more ($1.20–$3.00/ft²).
- Nitrile (Class B): when the gasket is wetted by oil or fuel continuously.
- Silicone (Class D) or BISCO® cellular silicone: above 105°C, or when flame and smoke ratings are required.
Closure design rules
- Target 25%–30% deflection. Below 15% the gasket may not take up flange flatness; above 40% closed-cell sponge takes permanent set and the force climbs steeply.
- Calculate the force: contact area × CFD. A 2A2 gasket with 20 in² of contact at 25% needs 100–180 lbf of clamping force spread across the fasteners.
- Use a compression stop or groove depth to fix deflection, so the gasket is not over-compressed when fasteners are torqued.
- Specify the skin: closed-cell sponge is sold with skin on one or both sides or skinless (split). Skin improves sealing; split surfaces bond better to PSA.
- Adhesive: EPDM is low-surface-energy. Use 3M 9474LE. Neoprene bonds well with 467MP / 468MP.
Run your gasket geometry in the gasket force calculator: enter the outer and inner dimensions of a picture-frame gasket and it returns the closure force range for each matching grade.