Engineering RFQs answered within 1 business dayrfq@technicalfoamservices.com

Materials

ASTM D1056 EPDM & neoprene gasket guide

A three-character callout like 2A2 tells the converter the cell structure, the oil resistance and the firmness of a sponge gasket. Here is how to read and choose it.

Decoding the callout

Type: 1 or 2

1 = open-cell sponge. 2 = closed-cell expanded rubber. Gaskets that must seal against water are almost always Type 2.

Class: A to D

A non-oil-resistant (EPDM). B oil resistant, low swell (nitrile). C oil resistant, medium swell (neoprene). D extreme temperature (silicone).

Grade: 0 to 5

Compression force deflection at 25%, from Grade 0 (softest) to Grade 5 (firmest). See the table below.

CFD grade table

GradeCFD @ 25% (psi)CFD @ 25% (kPa)Typical use
00–20–13.8Very low closure force, thin covers
12–513.8–34.5Light-duty enclosures, sheet-metal doors
25–934.5–62.1General enclosure and HVAC seals (most common)
39–1362.1–89.6Higher bolt load, vibration
413–1789.6–117.2Firm seals, heavy covers
517–25117.2–172.4Very firm, structural spacers
ASTM D1056 grade limits.

Common callouts

CalloutPolymerCFD @ 25%TemperatureWhere it is used
2A1EPDM2–5 psi−40 to +105°CLow-force outdoor seals, light enclosures
2A2EPDM5–9 psi−40 to +105°CHVAC, electrical enclosures, outdoor cabinets
2A3EPDM9–13 psi−40 to +105°CHigh bolt-load environmental gaskets
2B2Nitrile (NBR) blend5–9 psiPolymer dependentFuel and oil contact, low swell
2C2Neoprene / CR blend5–9 psi−40 to +93°CModerate oil, general industrial, HF-1 grades
2D2Silicone5–9 psiWide (silicone)High and low temperature extremes

EPDM or neoprene?

  • EPDM (Class A): the best weather, UV and ozone resistance of the common sponges and the lowest cost ($0.85–$2.80/ft² at 1/8"–1/4"). Swells in oil and fuel.
  • Neoprene / CR blends (Class C): medium oil and fuel resistance with good weathering, and UL 94 HF-1 on listed grades. Costs a little more ($1.20–$3.00/ft²).
  • Nitrile (Class B): when the gasket is wetted by oil or fuel continuously.
  • Silicone (Class D) or BISCO® cellular silicone: above 105°C, or when flame and smoke ratings are required.

Closure design rules

  1. Target 25%–30% deflection. Below 15% the gasket may not take up flange flatness; above 40% closed-cell sponge takes permanent set and the force climbs steeply.
  2. Calculate the force: contact area × CFD. A 2A2 gasket with 20 in² of contact at 25% needs 100–180 lbf of clamping force spread across the fasteners.
  3. Use a compression stop or groove depth to fix deflection, so the gasket is not over-compressed when fasteners are torqued.
  4. Specify the skin: closed-cell sponge is sold with skin on one or both sides or skinless (split). Skin improves sealing; split surfaces bond better to PSA.
  5. Adhesive: EPDM is low-surface-energy. Use 3M 9474LE. Neoprene bonds well with 467MP / 468MP.

Run your gasket geometry in the gasket force calculator: enter the outer and inner dimensions of a picture-frame gasket and it returns the closure force range for each matching grade.